Epidemiology and intervention for dysphotopsia
Positive dysphotopsias less common than negative but cause more disturbing symptoms
Cheryl Guttman Krader
Published: Sunday, September 15, 2019
[caption id="attachment_16590" align="alignleft" width="1024"] Nick Mamalis[/caption]
Dysphotopsias may be one of the most significant factors for patients having a negative outcome after uncomplicated cataract surgery.
Speaking at the clinical research symposium on “Understanding and Dealing With Dysphotopsias”, Nick Mamalis MD discussed the epidemiology of positive and negative dysphotopsias.
Positive dysphotopsias are less common than negative dysphotopsias, but they cause more disturbing symptoms. The aetiology appears to be related to IOL material, particularly hydrophobic acrylic and a square-edge design. Therefore, IOL exchange using an implant made of a different material is often immediately effective for resolving dysphotopsias, said Dr Mamalis, Professor of Ophthalmology, John A. Moran Eye Center, Salt Lake City, Utah, USA.
Negative dysphotopsias are likely also related to IOL material and design, but space between the iris and the IOL surface and the relationship of the anterior edge of the capsulotomy may also be contributing factors. Treatment may involve placement of an IOL in the ciliary sulcus or of an add-on IOL as well as reverse-optic capture of the existing IOL.
“However, negative dysphotopsias are more likely than positive dysphotopsias to resolve spontaneously. Therefore, when patients complain about this problem, surgeons should not rush to try to do something about it,” said Dr Mamalis.
Tags: clinical research, Dysphotopsia, epidemiology
Latest Articles
A New High for Hyperopia
Hyperopia patients can expect a rise in the array of treatments.
Research Committee is Engine Driving the Future of ESCRS
Commitment to evidence-based medicine anchors studies and other projects.
ESCRS EPICAT Study Updates
Early results suggest subconjunctival 10 mg triamcinolone an effective strategy for dropless cataract surgery.
Second Global Consensus on Keratoconus
Forthcoming position paper to provide an updated and expanded view on evaluation and management.
Automating Cataract Surgery Assessment
AI system measures eye stability and centration in procedures.
Post-LASIK Tonometer Takes ESCRS Innovators Den Prize
Good ideas lead to solutions to unmet needs.
ESCRS forms Functional Vision Working Group
Expanding the Limits of KLEx
Hyperopia treatment receives CE approval; mixed astigmatism may follow.