Arthur Cummings
Published: Thursday, August 27, 2015

Half-fluence verteporfin photodynamic therapy (PDT) is a useful treatment option for the treatment of central serous chorioretinopathy (CSC), the 2015 Irish College of Ophthalmologists annual conference in Westport, Ireland heard.

Christine Goodchild MD, University Hospital Galway, Ireland, reported positive results on optical coherence tomography (OCT) imaging following the procedure from a small-scale Irish study. She explained that CSC is characterised by neurosensory detachment and choriocapillaris leakage through the retinal pigment epithelium (RPE). While it usually resolves spontaneously, some patients experience persistent or recurrent leakage, so treatment is considered, usually after three months of acute CSC, she said.

“What you find with CSC is that these eyes have a very characteristic appearance in OCT and fundus fluorescein angiography (FFA) – you get this neurosensory retinal detachment on OCT and this smoke stack appearance, ink blot, or diffuse leakage on FFA,” said Dr Goodchild.

Dr Goodchild and colleagues carried out a study to determine the outcomes of patients who underwent half-fluence PDT treatment for CSC in University Hospital Galway over a four-year period.

Eleven patients (11 eyes) with chronic (unresponsive to other treatment) or persistent CSC after three months were involved in the study. The patients, with a mean age of 57 years, underwent a visual acuity check, a dilated fundal examination, OCT and FFA assessment at baseline, three months and six months follow-up. Investigators set out to determine if intraretinal and subretinal fluid resolved in the majority of cases, and if visual acuity was maintained, following half-fluence PDT treatment.

Patients were treated with half-fluence verteporfin PDT. Intravenous verteporfin was given at a dose of 3mg/m2 over 10 minutes and the delivered laser energy was half of the standard dose (half-fluence PDT), ie 25mj/cm2 over 83 seconds. The study outcome measures were best corrected visual acuity (BCVA), subretinal fluid thickness and central macular thickness. The baseline mean BCVA was LogMAR 0.4+/-0.21 (range 0.1-0.8) and at three months post-treatment was LogMAR 0.31+/-0.26 (range 0.1-1.7). Mean pre-PDT subretinal fluid thickness was 114+/-57µm, and post-PDT the mean was 41+/-57µm. Final visual acuity improved in seven cases, stabilised in two cases, and worsened in two cases. There was one post-PDT choroidal neovascular membrane (CNVM), a rare complication.

In all cases there was either resolution or improvement in subretinal fluid thickness. Dr Goodchild concluded that the study results were encouraging and, including the post-PDT CNVM, were in line with the published results to date internationally of using of half-fluence PDT for the treatment of active CSC.

 

Christine Goodchild: christine_siew88@yahoo.com

Latest Articles
Simulators Benefit Surgeons and Patients

Helping young surgeons build confidence and expertise.

Read more...

How Many Surgeries Equal Surgical Proficiency?

Internet, labs, simulators, and assisting surgery all contribute.

Read more...

Improving Clinical Management for nAMD and DME

Global survey data identify barriers and opportunities.

Read more...

Are Postoperative Topical Antibiotic Drops Still Needed?

Cataract surgeons debate the benefits of intracameral cefuroxime prophylaxis.

Read more...

Emerging Technology for Detecting Subclinical Keratoconus

Brillouin microscopy shows promise in clinical studies.

Read more...

Knowing Iris Repair: Modified Trifold Technique

Part eight of our series covers the modified trifold technique for large iris defects.

Read more...

It’s All About Biomechanics!

Increasing the pool of patients eligible for refractive surgery.

Read more...

Uncovering More Safe and Quick Options

Different strategies, such as PresbyLASIK, can offer presbyopes good outcomes.

Read more...

Topography-Guided PRK for Keratoconus

Improving visual acuity in patients with keratoconus.

Read more...

Defining AMD Treatment Protocol

Treatments trending to fewer injections for better results.

Read more...