JCRS HIGHLIGHTS
Thomas Kohnen, European Editor of JCRS


Thomas Kohnen
Published: Wednesday, December 1, 2021
Thomas Kohnen, European Editor of JCRS
TRIFOCAL IOLS AFTER REFRACTIVE SURGERY
Are current trifocal IOLs effective in eyes that have previously undergone photorefractive surgery? A retrospective comparative case study evaluated 868 eyes of 543 patients who had undergone corneal laser refractive surgery prior to receiving trifocal IOLs. This included 319 eyes treated for myopia and 549 eyes that had undergone treatment for hyperopia. Three months postoperatively, visual outcomes were poorer in the hyperopic group than those in the myopic group for mean CDVA (0.06 ± 0.05 vs 0.04 ± 0.04, P < .01) and safety (21% vs 12% of CDVA line loss, P < .05) outcomes. However, precision outcomes were worse in the myopic group, with a mean spherical equivalent of −0.38 ± 0.3 vs −0.17 ± 0.3 (P < .01). Patients with either high myopia or high hyperopia had poorer visual and safety results. R Cobo-Soriano et al., “Trifocal intraocular lens implantation in eyes with previous corneal refractive surgery for myopia and hyperopia”, 47(10): 1265–1272.
OPTIC EXCHANGE WITH MODULAR IOLS
A new modular IOL system with an exchangeable optic component compares favourably with standard IOL implantation both in terms of initial implantation and optic exchange procedures, concludes a prospective clinical study. Surgeons implanted 114 patients with a Harmoni Modular Intraocular Lens (HMIOL) in one eye (monovision target −1.50 dioptre) and a standard monofocal IOL in the contralateral eye. Patients could elect optic exchange three months after primary implantation. Sixty-five patients elected to have an optic exchange because of unsatisfactory visual outcomes from high monovision. No posterior capsular rupture occurred during optic exchange procedures. Short-term (12- month) posterior capsule opacification (PCO) evaluation showed that all eyes had PCO grade 1 or less at 12 months. No Nd:YAG capsulotomy was performed in the exchange cohort. The HMIOL is a hydrophobic acrylic foldable posterior chamber IOL system for implantation in the capsular bag. The HMIOL has an exchangeable optic (5.8mm diameter) and separate base component (13.0mm diameter) with an annular groove for attachment of the optic component. R Ang et al., “Evaluation of safety after optic exchange of a modular intraocular lens”, 47(10): 1273–1278.
ANGLE α AND OCULAR BIOMETRY
There is a significant inverse correlation between axial length and the angle α magnitude, a prospective, cross-sectional study concludes. The study evaluated 74 eyes in 74 healthy patients. Patients underwent a complete ophthalmological assessment, including biomicroscopy and biometry. The investigators used an OPD-Scan III analyser to assess both the angle α distance and biometry parameters. Hyperopic patients tended to demonstrate significantly higher angle α values when compared with myopic patients. Hyperopic eyes with steeper mean keratometry and lesser white-to-white distance also had an increased α angle.
C Velasco-Barona et al., “Impact of correlation of angle α with ocular biometry variables”, 47(10): 1279–1284.
JCRS is the official journal of ESCRS and ASCRS.

Latest Articles
Organising for Success
Professional and personal goals drive practice ownership and operational choices.
Update on Astigmatism Analysis
Is Frugal Innovation Possible in Ophthalmology?
Improving access through financially and environmentally sustainable innovation.
iNovation Innovators Den Boosts Eye Care Pioneers
New ideas and industry, colleague, and funding contacts among the benefits.
José Güell: Trends in Cornea Treatment
Endothelial damage, cellular treatments, human tissue, and infections are key concerns on the horizon.
Making IOLs a More Personal Choice
Surgeons may prefer some IOLs for their patients, but what about for themselves?
Need to Know: Higher-Order Aberrations and Polynomials
This first instalment in a tutorial series will discuss more on the measurement and clinical implications of HOAs.
Never Go In Blind
Novel ophthalmic block simulator promises higher rates of confidence and competence in trainees.
Simulators Benefit Surgeons and Patients
Helping young surgeons build confidence and expertise.