INFANT TONOMETRY

INFANT TONOMETRY
[caption id='attachment_4445' align='alignright' width='200'] Maurizio Uva MD[/caption]

Measuring IOP in infants can be a challenging task, requiring a consistent methodology and an assessment of the measurements that is in context with a patient’s entire clinical examination, according to Maurizio Uva MD, University of Catania, Italy. “The difficulties in measuring tonometry in infants include the lack of cooperation on the part of the infant, the effects of anaesthesia on IOP and the changing thickness of the cornea as a child ages. Moreover, there is little data as to what is the normal IOP in an infant eye,†Dr Uva said at the Glaucoma Day session of the XXX Congress of the ESCRS.

Dr Uva noted that results from a study carried out at Johns Hopkins University School of Medicine indicate that when infants are under sedation with ketamine their IOP will be closer to their IOP without sedation or anaesthesia than is the case when the anaesthetic gas sevoflurane is used (Blumberg et al, Am J Ophthalmol. 2007;143:494-499). Research supports the use of the Tono- PenR (Reichert) in paediatric cases, Dr Uva said. He cited a study that compared intraocular tonometry values with those obtained by three different non-invasive tonometers in children’s eyes. It showed that the Tono-pen measurements were closest to the intraocular values. The Schiotz tonometer tended to underestimate IOP, and the Perkins tonometer tended to overestimate IOP (Lasseck et al, Graefes Arch Clin Exp Ophthalmol. 2008;246:1463- 1466).

The IcareR tonometer (Icare Finland Oy), which is designed for measurements to be taken at home without a doctor’s supervision, may also be a useful option, Dr Uva said. The new magnetic design in particular could provide advantages in paediatric patients because it allows measurements to be taken while the patient is in a supine position, he added. He noted that in a study involving 71 eyes of 71 children with known or suspected glaucoma, IOP measured with the Icare tonometer was on average within about 3.6 mmHg of measurements obtained with Goldmann applanation tonometry (Flemmons et al, J AAPOS. 2011 Apr;15(2):153-157). Changes in corneal thickness as an infant’s eyes mature can also influence tonometry readings, Dr Uva said. He noted that in a study he and his associates conducted, newborns had a significantly higher IOP and corneal thickness than full-term newborns (Uva et al, J AAPOS 2011;15(4):367-9).

The findings of another study suggest that IOP increases during the first decade following birth. The study showed that mean IOP measured with a Perkins applanation tonometer is under 8.0 mmHg before age of three months and under 12.0 mmHg between ages of six and nine months and thereafter increases by about 1.0 mmHg per year up to 12 years (Bresson-Dumont, Journal Français d'Ophtalmologie; 32: 176–181). “The take-home message is to always include pachymetry in clinical examination, always use the same tonometer and, if possible the same anaesthesia. Moreover, since we don’t yet know for certain the normative IOP values in infants, tonometry has to be correlated with the whole clinical examination including biomicroscopy, gonioscopy, oculometry and optic disc evaluation,†Dr Uva concluded.

Latest Articles
Organising for Success

Professional and personal goals drive practice ownership and operational choices.

Read more...

Update on Astigmatism Analysis

Read more...

Is Frugal Innovation Possible in Ophthalmology?

Improving access through financially and environmentally sustainable innovation.

Read more...

iNovation Innovators Den Boosts Eye Care Pioneers

New ideas and industry, colleague, and funding contacts among the benefits.

Read more...

From Concept to Clinic

Partnerships with academia and industry promote innovation.

Read more...

José Güell: Trends in Cornea Treatment

Endothelial damage, cellular treatments, human tissue, and infections are key concerns on the horizon.

Read more...

Making IOLs a More Personal Choice

Surgeons may prefer some IOLs for their patients, but what about for themselves?

Read more...

Need to Know: Higher-Order Aberrations and Polynomials

This first instalment in a tutorial series will discuss more on the measurement and clinical implications of HOAs.

Read more...

Never Go In Blind

Novel ophthalmic block simulator promises higher rates of confidence and competence in trainees.

Read more...

Simulators Benefit Surgeons and Patients

Helping young surgeons build confidence and expertise.

Read more...