ESCRS - Challenging dysphotopsia

Challenging dysphotopsia

New lens may fix the old problem of negative dysphotopsia

Challenging dysphotopsia
Dermot McGrath
Dermot McGrath
Published: Thursday, February 1, 2018
Péter Vámosi MD
Initial trials of an intraocular lens specifically designed to counteract negative dysphotopsia indicate that the lens is safe, well tolerated and effective at relieving patients of undesired optical complications after cataract surgery, according to Péter Vámosi MD, PhD, Péterfy Sándor Hospital, Budapest, Hungary. “With the latest version of the lens, no patients reported negative dysphotopsia after implantation,” Dr Vámosi told delegates attending the XXXV ESCRS Congress in Lisbon. Post-cataract dysphotopsia typically presents in two principal forms: negative dysphotopsia, with a dark crescent in the temporal field of vision, or positive dysphotopsia, with light streaks, arcs, flashes or starbursts. Although likely multifactorial in cause, experience suggests that negative dysphotopsia occurs only with “in-the bag” IOLs and is prevented, relieved or improved when the IOL optic edge overlaps the anterior capsulotomy, either sulcus placed or with reverse optic capture, said Dr Vámosi. Based on an idea by Samuel Masket MD, the Morcher 90S anti-dysphotopic IOL, which has received the European CE mark, was designed with a peripheral groove to accept the anterior capsule edge, allowing the bulk of the IOL to remain in the capsule bag with a portion overlying the capsule to avoid negative dysphotopsia. Part of the optic overlies the capsule rather than vice versa, explained Dr Vámosi. The lens simulates reverse optic capture, a technique in which the anterior capsule edge is freed from the optic, and the optic is then elevated anterior to the capsulorhexis or capsule edge. While initial results in the first 39 cases showed no incidence of negative dysphotopsia, other complications included capsule block in three patients and optic capture in another two cases. In a design modification, fenestrations in the peripheral optic-haptic junction were created, which solved the problem of capsule block. However, optic capture was still an issue in five out of 48 subsequent implantations of the lens, said Dr Vámosi. Further modifications to the lens design, this time extending the anterior optic from 6.0mm to 6.4mm, seems to have resolved the issue once and for all. “In 13 cases of the latest version of the IOL implanted, there has been no incidence of negative dysphotopsia, no capsule block and no iris-optic capture,” said Dr Vámosi. While the manufacturer recommends using a femtosecond laser to perform an anterior capsulotomy of 4.8-4.9mm, Dr Vámosi said that his own personal experience of more than 50 implantations of the IOL shows that a 4.5-5.5mm manual capsulorhexis also works well. In addition to the absence of negative dysphotopsias, fixation within the anterior capsulotomy confers other advantages such as stable fixation, avoidance of anterior capsule contraction, absence of lens tilt, a stable toric axis, excellent centration, a more predictable effective lens position and decreased higher-order aberrations, he said. Péter Vámosi: vamosipeter@freemail.hu
Latest Articles
Diamonds in the Rough

The push for inclusivity in ophthalmology.

Read more...

Making Female Leadership More than a Moment

A remarkable global confluence of women in key positions.

Read more...

ESCRS Talks Technology at AAO

Europe adopts technological advances, US still waiting for lenses and lasers.

Read more...

Sorting Out Simultaneous Vision IOLs

The ESCRS Eye Journal Club discuss a new landmark paper on IOL classification and the need for harmonisation of terminology for presbyopic IOLs.

Read more...

Big Advantages to Small-Aperture IOLs

Small-aperture IOLs offer superior image quality with increased range of focus.

Read more...

Prioritising Self-Care

Benefits of maintaining physical, emotional, and mental health extend beyond the personal sphere.

Read more...

Valuing Clinical Trial Design

How inclusivity and diversity can enhance scientific accuracy in research.

Read more...

Knowing Iris Repair: Using Iridodiathermy in Iris Surgery

Prepare for decentred pupils and uneven irides in multiple situations.

Read more...

Neuroprotectant Treatment for MacTel Type 2

Intravitreal implant releasing ciliary neurotrophic factor found safe and effective in pivotal trials.

Read more...

Supplement: Maximizing Visual Quality in Refractive Surgery Through Enhanced Precision and Safety

Read more...