Phakic IOL comparison

Two different posterior capsule IOLs show comparable performance.

Phakic IOL comparison
Roibeard O’hEineachain
Roibeard O’hEineachain
Published: Saturday, May 1, 2021
Suphi Taneri MD, FEBOS-CR
The implantable phakic contact lens (IPCL, Care Group) and the implantable collamer lens (ICL, Staar Surgical) provide similar visual outcomes with similar refractive predictability and safety in the correction of moderate-to-high myopia with or without astigmatism, according to a study presented by Suphi Taneri MD, FEBOS-CR, Ruhr-University Bochum, Germany. The observational consecutive case series study included 111 eyes that underwent implantation of the IPCL and 115 eyes that underwent implantation of the ICL. Eyes with an internal anterior chamber depth of less than 2.8mm and a central endothelial cell count of less than 2000/cm2were excluded from the study, Dr Taneri told the 25th ESCRS Winter Meeting. He noted that the lenses have similar designs with regard to their dimensions, haptic design and the inclusion of a central hole to allow flow of the aqueous. They differ slightly in their lens material and in the available power range (IPCL: +15 to -30D, Cylinder up to 12D; ICL: +10 to -20D, Cylinder up to 6D) and sizes (IPCL: 13 sizes from 11.0 to 14.0mm; ICL: four sizes from 12.1 to 13.7mm). At three months’ follow-up, uncorrected distance visual acuity among eyes targeted for plano was the same or better than preoperative corrected distance visual acuity in 86% of eyes in the IPCL group and 91% of the ICL group. Furthermore, 35% and 38%, respectively, gained one or more lines in corrected distance acuity, Dr Taneri said. In eyes undergoing correction of up to -20D of myopia, the spherical equivalent was within 1.0D of target refraction in 92% of the IPCL group and 94% of the ICL group. Furthermore, postoperative cylinder was less than 1.0D in 97% and 95% of the IPCL and ICL group, respectively. Moreover, refraction was stable throughout one year of follow-up with both lenses. Dr Taneri noted that a review of all ICLs and IPCLs implanted over the past 10 years at his centre indicates that postoperative re-rotation was necessary in five of 58 toric IPCL implanted from 2017 to February 2021, compared to two eyes of 64 toric ICLs implanted from 2011 to 2019. However, he pointed out that vaulting was perfect in all cases where rotation occurred and he speculated that iris factors may be at fault. He also reported that there was no significant endothelial cell loss with either lens at two years’ follow-up. Intraocular pressure returned to preoperative levels after a spike in the first hours after implantation, while cataracts occurred in one eye in the IPCL group and two eyes in the ICL group.
Tags: Phakic IOL
Latest Articles
Nutrition and the Eye: A Recipe for Success

A look at the evidence for tasty ways of lowering risks and improving ocular health.

Read more...

New Award to Encourage Research into Sustainable Practices

Read more...

Sharing a Vision for the Future

ESCRS leaders update Trieste conference on ESCRS initiatives.

Read more...

Extending Depth of Satisfaction

The ESCRS Eye Journal Club discuss a new study reviewing the causes and management of dissatisfaction after implantation of an EDOF IOL.

Read more...

Conventional Versus Laser-Assisted Cataract Surgery

Evidence favours conventional technique in most cases.

Read more...

AI Scribing and Telephone Management

Automating note-taking and call centres could boost practice efficiency.

Read more...

AI Analysis and the Cornea

A combination of better imaging and AI deep learning could significantly improve corneal imaging and diagnosis.

Read more...

Cooking a Feast for the Eyes

A cookbook to promote ocular health through thoughtful and traditional cuisine.

Read more...

Need to Know: Spherical Aberration

Part three of this series examines spherical aberration and its influence on higher-order aberrations.

Read more...

Generating AI’s Potential

How generative AI impacts medicine, society, and the environment.

Read more...