Optic disc margin should be abandoned

Advances in spectral-domain optical coherence tomography present new paradigm in glaucoma imaging

Optic disc margin should be abandoned
Roibeard O’hEineachain
Roibeard O’hEineachain
Published: Wednesday, March 30, 2016
[caption id="attachment_6636" align="alignnone" width="350"]Nick Strouthidis discusses glaucoma imaging Nick Strouthidis discusses glaucoma imaging[/caption]

Using a clinician-defined disc margin to assess neuroretinal rim should be abandoned in favour of using Bruch’s membrane opening-minimum rim width (BMO-MRW) measurements performed with spectral-domain optical coherence tomography (SD-OCT), said Nick Strouthidis MBBS, MD, PhD, FRCS, FRCOphth, FRANZCO at a Glaucoma Day session at the XXXIII Congress of the ESCRS in Barcelona.

“The disc margin defines the outermost limit of the neuroretinal rim. Accurate, reproducible measurement of its location is essential for the quantification of changes in the optic nerve head in glaucoma. However, the disc margin as defined by the clinician does not correspond to any consistent anatomical landmark and therefore is essentially a meaningless theoretical construct. Therefore, quantifying change based on the clinician’s definition of the disc margin is error-prone,” said Dr Strouthidis, Moorfields Eye Hospital, London, UK.

When using optic disc stereophotographs, clinicians define the disc margin as the inner aspect of Elschnig’s ring, a white reflective ring internal to the termination of the retinal pigment epithelium. However, studies show that different clinicians viewing the same stereophotograph will invariably mark its location differently.

Moreover, studies involving optic disc stereophotographs co-localised with SD-OCT-based delineations of the neuroretinal rim’s dimensions have failed to identify a consistent anatomical basis for the disc margin as defined by clinicians. The outer limit of the disc’s neural tissue as defined by SD-OCT is the innermost edge of Bruch’s membrane, the BMO, which may be invisible by ophthalmoscopy or in stereophotographs. It represents the narrowest aperture through which the neural tissue passes and is easily and reliably imaged using SD-OCT.

The advent of SD-OCT represents a true turning point in the imaging of the optic nerve head, Dr Strouthidis noted. Time-domain OCT had poor neuroretinal rim penetration. SD-OCT is faster and has better penetration and is therefore is much more capable of imaging the finer neuroretinal tissue structures.

He added that to provide a precise and consistent demarcation of the neuroretinal rim, it should be defined as being where the distance is shortest between the BMO and the internal limiting membrane, that is, the BMO-MRW.

The BMO-MRW parameter is potentially better for phenotyping glaucoma suspects than OCT peripapillary retinal nerve fibre layer thickness or Heidelberg retinal tomography (HRT Heidelberg Engineering) Moorfields regression analysis. It is the first optic disc parameter to change in the primate model of glaucoma. BMO-MRW measurements are now included in the optic nerve head parameters of Heidelberg Engineering’s Glaucoma Module Premium Edition (GMPE) for the Spectralis.

Nick Strouthidis: nick.strouthidis@moorfields.nhs.uk

Declaration of Interest: Nick Strouthidis received lecture fees and travel expenses from Heidelberg Engineering

Latest Articles
Nutrition and the Eye: A Recipe for Success

A look at the evidence for tasty ways of lowering risks and improving ocular health.

Read more...

New Award to Encourage Research into Sustainable Practices

Read more...

Sharing a Vision for the Future

ESCRS leaders update Trieste conference on ESCRS initiatives.

Read more...

Extending Depth of Satisfaction

The ESCRS Eye Journal Club discuss a new study reviewing the causes and management of dissatisfaction after implantation of an EDOF IOL.

Read more...

Conventional Versus Laser-Assisted Cataract Surgery

Evidence favours conventional technique in most cases.

Read more...

AI Scribing and Telephone Management

Automating note-taking and call centres could boost practice efficiency.

Read more...

AI Analysis and the Cornea

A combination of better imaging and AI deep learning could significantly improve corneal imaging and diagnosis.

Read more...

Cooking a Feast for the Eyes

A cookbook to promote ocular health through thoughtful and traditional cuisine.

Read more...

Need to Know: Spherical Aberration

Part three of this series examines spherical aberration and its influence on higher-order aberrations.

Read more...

Generating AI’s Potential

How generative AI impacts medicine, society, and the environment.

Read more...