CLASSICAL VS. MODERN IOL POWER CALCULATION FORMULAE: IMPACT OF THE ESCRS POWER CALCULATOR ON IOL POWER CHOICE
Published 2025 - 29th ESCRS Winter Meeting
Reference: PP02.01 | Type: Presented Poster & Poster | DOI: 10.82333/bjy8-sf47
Authors: Lisa Tasch 1 , Leon Pomberger 1 , Christoph Mayer-Xanthaki 2 , Sophia Anna Reifeltshammer* 1 , Matthias Bolz 1 , Nino Hirnschall 1
1Ophthalmology and Optometry,Johannes Kepler University,Linz,Austria;Ophthalmology and Optometry,Kepler University Clinic,Linz,Austria, 2Ophthalmology,Medical University Graz,Graz,Austria
Purpose
Setting
Department of Ophthalmology and Optometry, Kepler University Clinic, Linz, Austria
Department of Ophthalmology, Medical University Graz, Graz, Austria
Methods
Results
In total, 337 eyes of 337 patients were included in this trial. The data showed an average axial eye length of 23.43 mm (SD: 1.27) and an average anterior chamber depth of 3.07 mm (SD: 0.40).
The best performing modern formulae were Kane and Barrett Universal II with a mean absolute error (SD) of 0.37 (0.31) and 0.39 (0.32) dpt. The results demonstrated a significant difference between the mean absolute error (MAE) of modern formulae compared to classical formulae with p<0.01. Furthermore, using the ESCRS IOL power calculator saves an average of 5 minutes and 38.2 seconds per patient compared to a separate data input for each modern formula on their website. The total results of 337 eyes will be presented at the ESCRS meeting.
Conclusion