Eight Year Follow-Up Of Artiflex And Artiflex Toric Phakic Intraocular Lens
Published 2022
- 40th Congress of the ESCRS
Reference: PP27.07
| Type: ESCRS 2022 - Posters
| DOI:
10.82333/pv9s-9s91
Authors:
Mariano Royo* 1
, ANGEL JIMENEZ 1
1Oftalmología,Instituto Oftalmológico de Madrid / Hospital San Rafael,Fuenlabrada,Spain
Purpose
To analyze long-term efficacy, safety, visual and refractive stability, and physiological changes of Artiflex Myopia and Toric phakic intraocular lenses (pIOL) separately throughout an 8-year follow-up.
Setting
Retrospective cohort study.
The study population is comprised of 67 eyes of 37 patients underwent Artiflex Myopia (47 eyes) or Artiflex Toric (20 eyes) implantation for correcting myopia and/or astigmatism. Follow-up evaluations were performed 1, 3, 5, and 8 years after surgery.
Methods
67 eyes of 37 patients underwent Artiflex Myopia (47 eyes) or Artiflex Toric (20 eyes) implantation for correcting myopia and/or astigmatism. Follow-up evaluations were performed 1, 3, 5, and 8 years after surgery. Preoperative and postoperative data included corrected (CDVA) and uncorrected distance visual acuity (UDVA), manifest refraction, endothelial cell density (ECD), and intraocular pressure (IOP) assessments. Efficacy and safety indexes were analyzed. The vectorial analysis was performed using the Thibos method.
Results
Mean CDVA and UDVA of both pIOLs significantly improved from preoperative to 1 year after implantation, and then it remained stable over the 8-year follow-up. The efficacy and safety indexes after 8 years were 0.94 ± 0.16 and 1.07 ± 0.18 for Artiflex Myopia and 1.00 ± 0.11 and 1.10 ± 0.15 for Artiflex Toric, respectively. The spherical equivalent (SE) significantly improved after surgery. J0, J45 and SE refractive components showed no changes between postoperative visits. A total ECD loss of 4.8% (p<0.001) and 10.4% (p=0.005) was found after 8 years for Artiflex Myopia and Toric, respectively.
Conclusions
Artiflex Myopia and Toric pIOLs are a safe, efficient and predictable option for the correction of myopia and/or astigmatism. The vectorial analysis showed excellent rotation stability for the toric version.