Purpose
To assess the efficacy of computerized vergence and accommodation training for asthenopia.
Setting
Krishna Eye Centre, Mumbai, India
Methods
Five sessions of vergence and accommodation training were given to 1222 subjects with Bynocs computerized software program in subjects having asthenopia symptom score of more than 12 and with either accommodation infacility or convergence insufficiency or both. History of migraine, sinusitis, spine problem and any intraocular surgery
Results
Out of 1222 symptomatic subjects, 489 (40 percent) had accommodation related issues, 428 (35percent) had accommodation & fusional vergence anomalies and 305 (25 percent) had convergence insufficiency. All subjects showed clinically significant reduction in asthenopia symptom score (p Values =0.0001) post 5 sessions of Bynocs therapy
Conclusions
Computerized vergence and accommodation training is effective in treating asthenopia. Need to conduct large scale study with control group to know the placebo / true effect of Bynocs computerized software program.